$1M in Fines After Nitrogen Kills 6 at Georgia Poultry Plant

479

Source: US News

Federal workplace safety officials are proposing nearly $1 million in fines against four companies following a January liquid nitrogen leak that killed six workers at a northeast Georgia poultry processing plant.

Federal workplace safety officials are proposing nearly $1 million in fines against four companies following a January liquid nitrogen leak that killed six workers at a northeast Georgia poultry processing plant.

Foundation Food Group, which owns the Gainesville plant, was cited for 26 violations with a proposed fine of $595,474. Packers Sanitation Services Ltd., which provided cleaning services at the plant, was cited for 19 violations with a proposed fine of $286,720. Messer LLC, which delivered the nitrogen, was cited for six violations and faces a proposed fine of $74,118. FS Group Inc, which manufacturers and services equipment, was cited for eight violations with a proposed fine of $42,325.

OSHA fines and citations are often lowered following informal and formal appeal processes.

Foundation Food did not immediately reply to an email seeking comment.

The plant takes chicken slaughtered elsewhere and prepares items such as patties and nuggets for food service operations, freezing them for shipment.

It was a new freezing line that went horribly wrong on the morning of Jan. 28, sending a cloud of liquid nitrogen vapor into a room that was below the floor level of the rest of the plant. Workers tried to flee, but found some exits blocked, investigations have found.

Six workers died from “asphyxia due to, or as a consequence of liquid nitrogen exposure” including 45-year-old Jose DeJesus Elias-Cabrera of Gainesville; 35-year-old Corey Alan Murphy of Clermont; 28-year-old Nelly Perez-Rafael of Gainesville; 41-year-old Saulo Suarez-Bernal of Dawsonville; 38-year-old Victor Vellez of Gainesville; and 28-year-old Edgar Vera-Garcia of Gainesville. Others were hospitalized from nitrogen exposure.

The U.S. Chemical Safety Board has previously said that a newly installed conveyor belt system that carried chicken products into a liquid nitrogen bath malfunctioned.

Workers reported that a computerized measuring system indicated a low liquid level in the immersion bath, according to the board. The processing line that malfunctioned had been shut down on the morning of the release, the board said

Foundation Food Group had previously said it was “fully cooperating” with investigators, but OSHA officials said Friday that they had issued numerous subpoenas for documents and testimony to compel cooperation.

They also for the first time acknowledged that they had asked the Department of Homeland Security to stop immigration enforcement in Hall County, where the hub of Georgia’s nation-leading poultry processing industry is heavily staffed by people who entered the country illegally.

“During the course of this inspection we have had difficulty in reaching workers, particularly, many of the workers are immigrants, undocumented immigrants,” said OSHA Atlanta Regional Administrator Kurt Petermeyer.

Families of a number of dead workers have filed lawsuits against the German company that made the liquid nitrogen system, Messer Group, and a Messer employee who visited the plant in the days before the leak to service the system. Those suits allege Messer and the worker are at fault for failing to properly inspect, test, repair or shut down the system before the liquid nitrogen release.