Basic Husbandry for Turkeys

906

Table of Contents

  1. Handy Hints
 Criteria Norms During Growth Norms After Maturity Trouble Shooting Checklist
Temperature

(At birds height)

Under Brooders

Day Old – 1 week:
35°C
1-2: 32°C
2-3: 29°C
3-4: 27°C
4-5: 21-24°C

Room Temperature

21-22°C

(Bird’s comfort)

Too High: pasty cloacas, spreading and flapping, crowding away from heat source

Too Low: feather ruffling, huddling and piling near heat source

Ammonia (P.P.M.) Maximum: 25 ppm (see next page) Maximum: 25 ppm Too High: eye burns, higher incidence of breast blisters – leg problems
Air Movement 0.11 m3 per minute per kg live bird

or

2.75-3.0 cfm per kg live bird

0.11 m3 per minute per kg live bird

or

2.75-3.0 cfm per Kg live bird

Poor: high ammonia levels, wet, caked litter, Respiratory problems, increased foot problems, poor growth because of wet litter
(see next page)
Lighting First 5 Days:
50 lux

After 1 week: adequate light for feeding and activity

Daylight Interval

Intensity must be 10 X greater than DARK interval to ensure good production levels

Too High: cannibalism, flighty, nervous behaviour

Too Low: poor intakes, poor growth and feed conversion
Feeder Space
(per bird) – ad lib

Water Trough
(per bird)

0.4 wks. – 3.5 cm
4-12 wks. – 8.0 cm
12 weeks – mature

Feed – 10-12 cm
Water – 10-12 cm

Too Small: poor intakes, poor growth and starveouts
Density – Floor or Cage Space

(per bird)

Hens

0-4 weeks: 0.5 m2
4-8 weeks: 0.22 m2
8-12 weeks: 0.3 m2

Toms

0-4 weeks: 0.5 m2
4-8 weeks: 0.25 m2
8-12 weeks: 0.30 m2

Hens

12-16 weeks
16-20 weeks
at least 0.3 m2/bird

Toms

12-16 weeks
16-20 weeks
at least 0.4 m2/bird

Too Dense: feather picking, cannibalism, more injuries, more health problems, poorer carcasses or lower feed efficiency, wet litter – leg problems

Handy Hints

Humans can detect the smell of ammonia at 7 p.p.m.

When human eyes are affected (watering/burning), ammonia levels are at least 20 p.p.m.

Fan Diameter in Inches Fan Capacity, CFM
 8 200
10 400
12 1000
14 1500
16 2000
18 3000
20 4000
24 5000
30 7000
36 10000

 

Figure 1. Guideline: Lamping Requirements for Poultry Chart. Shows Number of Square Feet per 60 Watt Bulb. Peter Nicholas, Energy Advisor – Agriculture, Ontario Hydro

Text Equivalent of Figure 1

Example (Real Barn):

A maintained light level of 20 lux may be achieved by using one standard 60W/120V incandescent bulb for every 200 square feet of floor space, or by using one long-life 60W/130V incandescent bulb for every 120 square feet of floor space in a dark barn.

Example (Research Lab):

A white clean room will have 40 lux with about one lamp per 280 square feet, or about 20 lux if one bulb per 560 square feet is used.

  • Save Energy: Use 9 Watt to 11 Watt compact fluorescent lamps instead of 60 Watt/130 Volt incandescent bulbs
  • Save Energy: Use 13 Watt to 15 Watt compact fluorescent lamps instead of 60 Watt/120 Volt incandescent bulbs

 

For more information:
Toll Free: 1-877-424-1300
E-mail: ag.info.omafra@ontario.ca